Aligning a structure to another¶
We use align.alignto
to align a structure to another.
Last updated: June 26, 2020 with MDAnalysis 1.0.0
Minimum version of MDAnalysis: 1.0.0
Packages required:
Optional packages for molecular visualisation:
See also
Note
MDAnalysis implements RMSD calculation using the fast QCP algorithm ([The05]) and a rotation matrix R that minimises the RMSD ([LAT09]). Please cite ([The05]) and ([LAT09]) when using the MDAnalysis.analysis.align
module in published work.
[1]:
import MDAnalysis as mda
from MDAnalysis.analysis import align
from MDAnalysis.tests.datafiles import CRD, PSF, DCD, DCD2
import nglview as nv
Loading files¶
The test files we will be working with here are trajectories of a adenylate kinase (AdK), a phosophotransferase enzyme. ([BDPW09]) The trajectories sample a transition from a closed to an open conformation.
[2]:
adk_open = mda.Universe(CRD, DCD2)
nv.show_mdanalysis(adk_open)
[3]:
adk_closed = mda.Universe(PSF, DCD)
nv.show_mdanalysis(adk_closed.atoms)
Currently, the proteins are not aligned to each other. The difference becomes even more obvious when the closed conformation is compared to the open. Below, we set adk_open
to the last frame and see the relative positions of each protein in a merged Universe.
[4]:
adk_open.trajectory[-1] # last frame
merged = mda.Merge(adk_open.atoms, adk_closed.atoms)
nv.show_mdanalysis(merged)
Aligning a structure with align.alignto¶
alignto
(API docs) aligns the mobile AtomGroup to the target AtomGroup by minimising the root mean square deviation (RMSD) between particle positions (please see the linked notebook for an explanation of RMSD). It returns (old_rmsd, new_rmsd). By default (match_atoms=True
), it will attempt to match the atoms between the mobile and reference structures by
mass.
[5]:
rmsds = align.alignto(adk_open, # mobile
adk_closed, # reference
select='name CA', # selection to operate on
match_atoms=True) # whether to match atoms
print(rmsds)
nv.show_mdanalysis(mda.Merge(adk_open.atoms, adk_closed.atoms))
(21.712154435976014, 6.817293751703919)
However, you may want to align to a structure that where there is not a clear match in particle mass. For example, you could be aligning the alpha-carbons of an atomistic protein to the backbone beads of a coarse-grained structure. Below, we use the somewhat contrived example of aligning 214 alpha-carbons to the first 214 atoms of the reference structure. In this case, we need to switch match_atoms=False
or the alignment will error.
[6]:
rmsds = align.alignto(adk_open.select_atoms('name CA'), # mobile
adk_closed.atoms[:214], # reference
select='all', # selection to operate on
match_atoms=False) # whether to match atoms
print(rmsds)
nv.show_mdanalysis(mda.Merge(adk_open.atoms, adk_closed.atoms))
(18.991465038265208, 16.603704620787127)
When we align structures, positions are set temporarily. If we flip to the first frame of adk_open
and back to the last frame, we can see that it has returned to its original location.
[7]:
adk_open.trajectory[0] # set to first frame
adk_open.trajectory[-1] # set to last frame
nv.show_mdanalysis(mda.Merge(adk_open.atoms, adk_closed.atoms))
You can save the aligned positions by writing them out to a PDB file and creating a new Universe.
[8]:
align.alignto(adk_open, adk_closed, select='name CA')
adk_open.atoms.write('aligned.pdb')
nv.show_mdanalysis(mda.Universe('aligned.pdb'))
/Users/lily/anaconda3/envs/mda-user-guide/lib/python3.7/site-packages/MDAnalysis/coordinates/PDB.py:864: DeprecationWarning: Using the last letter of the segid for the chainID is now deprecated and will be changed in 2.0. In 2.0, the chainID attribute will be used if it exists, or a placeholder value.
"exists, or a placeholder value.", DeprecationWarning)
References¶
[1] Oliver Beckstein, Elizabeth J. Denning, Juan R. Perilla, and Thomas B. Woolf. Zipping and Unzipping of Adenylate Kinase: Atomistic Insights into the Ensemble of Open↔Closed Transitions. Journal of Molecular Biology, 394(1):160–176, November 2009. 00107. URL: https://linkinghub.elsevier.com/retrieve/pii/S0022283609011164, doi:10.1016/j.jmb.2009.09.009.
[2] Richard J. Gowers, Max Linke, Jonathan Barnoud, Tyler J. E. Reddy, Manuel N. Melo, Sean L. Seyler, Jan Domański, David L. Dotson, Sébastien Buchoux, Ian M. Kenney, and Oliver Beckstein. MDAnalysis: A Python Package for the Rapid Analysis of Molecular Dynamics Simulations. Proceedings of the 15th Python in Science Conference, pages 98–105, 2016. 00152. URL: https://conference.scipy.org/proceedings/scipy2016/oliver_beckstein.html, doi:10.25080/Majora-629e541a-00e.
[3] Pu Liu, Dimitris K. Agrafiotis, and Douglas L. Theobald. Fast determination of the optimal rotational matrix for macromolecular superpositions. Journal of Computational Chemistry, pages n/a–n/a, 2009. URL: http://doi.wiley.com/10.1002/jcc.21439, doi:10.1002/jcc.21439.
[4] Naveen Michaud-Agrawal, Elizabeth J. Denning, Thomas B. Woolf, and Oliver Beckstein. MDAnalysis: A toolkit for the analysis of molecular dynamics simulations. Journal of Computational Chemistry, 32(10):2319–2327, July 2011. 00778. URL: http://doi.wiley.com/10.1002/jcc.21787, doi:10.1002/jcc.21787.
[5] Hai Nguyen, David A Case, and Alexander S Rose. NGLview–interactive molecular graphics for Jupyter notebooks. Bioinformatics, 34(7):1241–1242, April 2018. 00024. URL: https://academic.oup.com/bioinformatics/article/34/7/1241/4721781, doi:10.1093/bioinformatics/btx789.
[6] Douglas L. Theobald. Rapid calculation of RMSDs using a quaternion-based characteristic polynomial. Acta Crystallographica Section A Foundations of Crystallography, 61(4):478–480, July 2005. 00127. URL: http://scripts.iucr.org/cgi-bin/paper?S0108767305015266, doi:10.1107/S0108767305015266.